Three-Phase Thermostat with Safety Cut-Out

Three-Phase Thermostat with Safety Cut-Out
Three-Phase Thermostat with Safety Cut-Out

Technical Specs
  • Maximum Current Intensity:     3 x 16 A - 230 V

Description

Three-phase thermostat with temperature range 30 – 70 ºC, with safety cut-out at 85 ºC. Maximum current intensity 3×16 Α at 230 V. The two phases are disrupted, hence should not be connected to neutral conductor. Available with snout length 300 mm or 450 mm.

Product Details:

Code 24130015: 300 mm – 3 x 16 A – 230 V

Code 24130016: 450 mm – 3 x 16 A – 230 V